OS2 MPO-12 APC 1-to-2 Breakout Cable
AI Data Center Fiber Cabling

OS2 MPO-12/APC 1-to-2 Breakout Cable

This OS2 single-mode breakout assembly converts one four-channel MPO-12/APC parallel-optics path into two two-channel MPO-12/APC branches for supported DR optical architectures. It is intended for longer rack-to-rack or row-to-row paths where the installed transceivers and channel loss budget call for single-mode fiber. The passive assembly does not independently determine data rate or reach.

Fiber type

OS2 single-mode, 9/125 µm

Fiber count

8 active fibers

Connector configuration

1 × MPO-12/APC female to 2 × MPO-12/APC female

Lane arrangement

One 4-channel side to two 2-channel branches

Interested in this product?

Send the model, quantity, target specification and required documents. Fibtele will confirm the configuration, MOQ, lead time and quality-control options.

Download technical configuration brief

This brief summarizes the published record. Request the exact drawing, test method, documents, quantity, MOQ, and lead time in the written quotation before ordering.

Specifications

ParameterValue
Fiber typeOS2 single-mode, 9/125 µm
Fiber count8 active fibers
Connector configuration1 × MPO-12/APC female to 2 × MPO-12/APC female
Lane arrangementOne 4-channel side to two 2-channel branches
PolarityType B; final lane map must be confirmed
Leg lengthsEqual or staggered by configuration
Jacket optionsLSZH / indoor-rated options by configuration
Compatibility requirementConfirm breakout mode, optical MDI, polish, gender, and channel loss

Description

This OS2 single-mode breakout assembly converts one four-channel MPO-12/APC parallel-optics path into two two-channel MPO-12/APC branches for supported DR optical architectures. It is intended for longer rack-to-rack or row-to-row paths where the installed transceivers and channel loss budget call for single-mode fiber. The passive assembly does not independently determine data rate or reach.

Product information is for selection and configuration reference. Confirm the final datasheet, test or compliance documents, warranty, and acceptance criteria before ordering.

Features

  • One four-channel MPO-12/APC side branches into two two-channel MPO-12/APC ends.
  • Eight active OS2 single-mode fibers are distributed across the two branch legs.
  • Type-B crossover construction supports compatible parallel-optics lane mappings.
  • Compact protected fanout with configurable branch identification.
  • Equal or staggered leg lengths support structured rack and pathway routing.
  • Designed for compatible single-mode breakout optics; confirm the transceiver operating mode before ordering.
  • Custom length, jacket, labeling, and test documentation are available subject to technical review.

Applications

  • DR parallel-optics breakout links
  • Inter-rack and row-to-row AI fabric cabling
  • GPU, DPU, switch, and storage interconnects
  • Twin-port optical fanout architectures using two assemblies
  • High-performance computing structured cabling

Frequently asked questions

Confirm the model, interfaces, dimensions, and the applicable parameters before quotation. The current record includes Fiber type: OS2 single-mode, 9/125 µm; Fiber count: 8 active fibers; Connector configuration: 1 × MPO-12/APC female to 2 × MPO-12/APC female; Lane arrangement: One 4-channel side to two 2-channel branches; the final drawing and compatibility review control the order.

Typical uses include DR parallel-optics breakout links; Inter-rack and row-to-row AI fabric cabling. Select the application only after checking the complete link, process, or installation requirements.

Available documents and test records depend on the ordered configuration. Request the applicable drawing, inspection or test method, and acceptance record; no MOQ, lead time, certification, or performance claim is implied without written confirmation.